Taking the misoperation and tripping as an example, when there is an instantaneous overvoltage due to other faults in the DC power system, or an error occurs in the operation threshold setting of the corresponding closing contactor of the circuit breaker, a malfunction occurs; the capacitance of the line conductor to the ground Current, if the line laying distance is too long, it can generate ground current, which affects the normal operation of the circuit breaker; when the zero line of the circuit load terminal is grounded, part of the charge current can flow into the earth, causing the circuit breaker to malfunction.
Finnish[fi]
Ottaen esiin virheellinen toiminta ja laukaisu, kun tasavirtajärjestelmän muista vioista johtuu hetkellinen ylijännite tai virran katkaisijan vastaavan sulkemiskontaktorin toimintakynnyksen asettamisessa tapahtuu toimintahäiriö; linjajohtimen kapasitanssi maavirtaan, jos linjan asettamisetäisyys on liian pitkä, se voi muodostaa maavirtaa, mikä vaikuttaa katkaisijan normaaliin toimintaan; kun piirikuormitusliittimen nollaviiva on maadoitettu, osa latausvirrasta voi virtaa maan päälle, aiheuttaen katkaisijan toimintahäiriön.